TCP IP Temp/Humidity Probe

ENVIROMUX-TRH-xx | TCP IP Temp Probe

ENVIROMUX-T-xx
|
- For use with ENVIROMUX-MINI.
- Applications from 0°C and 40°C (32°F to 104°F) and 20% to 80% relative humidity.
- High resistance to external influences on the cable due to digital output signal.
- Accurate to within ±0.75°C (±1.35°F) and ±5% relative humidity.
- Re-calibration is not necessary after initial set-up.
- Available lengths: 0.9/1.8/3/7.6 meters.
- Includes mounting hardware.
- Regulatory approvals: CE, FCC, RoHS.
|
- For use with ENVIROMUX-MINI.
- Applications from 0°C to 40°C (32°F to 104°F).
- High resistance to external influences on the cable due to digital output signal.
- Accurate to within ±0.75°C (±1.35°F).
- Re-calibration is not necessary after initial set-up.
- Available lengths: 0.9/1.8/3/7.6 meters.
- Includes mounting hardware.
- Regulatory approvals: CE, FCC, RoHS.
RoHS compliant.
|

ENVIROMUX-LDx-y |

ENVIROMUX-M-DCS |
- For warning of flooding.
- 100% waterproof electronics.
- Detects any conductive liquid.
- Puddle: 1.53 cm diameter.
- Detects liquid depth >0.25 cm.
- Supports water sensor cable lengths from 0.3 to 305 meters.
- Supports 2-wire cable lengths from 1.52 to 30.5 meters.
- Regulatory approvals: CE, FCC, RoHS
|
- Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary).
- Can also be used for monitoring side wall and covers.
- Includes mounting hardware.
- For normally closed circuit connection.
- 2-wire interface.
- Screw terminal.
- Wide actuating gap, approximately 25mm.
- Dimensions WxDxH (mm): 13x13x51 (Switch), 13x13x51 (Magnet).
|
TCP IP Humidity Probe

ENVIROMUX-RH-xx |

ENVIROMUX-SDS-PA |
- For use with ENVIROMUX-MINI.
- Applications from 20% to 80% relative humidity at temperatures between 0°C and 40°C.
- High resistance to external influences on the cable due to digital output signal.
- Accurate to within ±5% relative humidity.
- Re-calibration is not necessary after initial set-up.
- Available lengths: 0.9/1.8/3/7.6 meters.
- Includes mounting hardware.
- Regulatory approvals: CE, FCC, RoHS
|
- For warning of smoke.
- Built-in 57° C (135° F) thermal heat sensor.
- Includes mounting hardware.
- Photoelectric smoke detector.
- Screw terminal.
- Includes 9V/1A power supply.
- Regulatory approvals: UL
|

ENVIROMUX-EBS |

ENVIROMUX-T-IND-xx |
- Sends activation signal when button is pressed.
- For normally closed or normally open circuit connections.
- 2-wire interface.
- Screw terminal.
- Dimensions WxDxH (mm): 10x23x76
|
- For use with ENVIROMUX-MINI-IND.
- Applications from 0°C and 75°C (32°F to 167°F).
- High resistance to external influences on the cable due to digital output signal.
- Accurate to within ±1.25°C (±2.25°F).
- Re-calibration is not necessary after initial set-up.
- Available lengths: 0.9/1.8/3/7.6 meters.
- Dimensions WxDxH (mm): 50.8x63.5x25.4
- Includes mounting hardware.
- Regulatory approvals: CE, FCC, RoHS
|

ENVIROMUX-TDS | 
ENVIROMUX-AFM |
- Sends activation signal when tamper switch is released.
- Normally closed contact when depressed.
- Dimensions (mm): inner diameter: 20, outer diameter: 23, height: 74
- 2-wire interface.
|
- Reliable mechanical solution for monitoring
air flow.
- Reacts to any condition causing insufficient flow of air such as malfunctioning cooling fan, increased friction, or physical blockage.
- Can be used for direct monitoring of a cooling fan.
- Dimensions WxDxH (mm): 34x17.5x7.5
- Switch contact is closed when air flow is >2.5 m/s.
- Connection: 2x single strand AWG26, length 0.5 m.
- Available Lengths: 0.5/3/15.2/30.5/61/121.9/182.9/243.8/304.8 meters
- Regulatory approvals: RoHS
|
 ENVIROMUX-GSM-P
How to: Access the IMEI Number of the GSM Modem |

ENVIROMUX-POE
Application Note: ENVIROMUX-MINI Powered Over Ethernet |
- Sends SMS text messages to a pager or cell phone when a sensor goes out of range of a configurable threshold.
- GSM modem with antenna built into system.
- Convenient push-push SIM card holder
- Mini SIM card supporting SMS messaging required (not included)
- Protocols: AT commands
- Supports one configurable authorized phone number for sending SMS text messages.
- Auto PIN feature, no need to enter SIM card PIN after restart
- Quad band: 850/900/1800/1900 MHz
- SMS: Text mode
- Power: 110 or 220 VAC at 50 or 60 Hz via AC adapter.
- Regulatory Approvals: CE
|
- Enables ENVIROMUX-MINI to be powered over Ethernet connection.
- Eliminate the need to place ethernet-enabled devices near power outlets, giving more freedom of placement.
- Supply Power and Data up to 91 meters using standard Ethernet cabling.
- Outputs Power on an attached DC power cable, and Data on an attached Ethernet cable.
- Ethernet Pin Usage:
- Data: 1,2,3,6
- Power: 4,5,7,8
- No tools or software necessary for installation.
- Overload and short circuit protection.
- Standards: 802.3af
- Dimensions WxDxH (mm): 76x83x45
- Maximum power output: 5VDC @ 2.4A.
- Regulatory approvals: RoHS, FCC, CE
|

ENVIROMUX-2W-xx | 
ENVIROMUX-DCVD-24V-M |
- 2-wire sensor cable.
- Use to connect dry contact sensors to the ENVIROMUX-MINI.
- Available lengths: .9/1.8/3/7.6/15.2/30.5 meters
|
- Measurement range: detects voltage from 24-36 VDC.
- Contacts remain closed between 26-36 VDC
- Contacts open when monitored voltage drops below 24 VDC
- Measurement indication: Alarm or Normal.
- Sensor type: open/closed contact switch.
- Includes 6-foot 2-wire cable to connect to the ENVIROMUX-MINI.
- Attached 3-foot power cord with tinned leads on 3 wires.
- For use with ENVIROMUX-MINI purchased on or after 11/1/2007.
- Regulatory approvals: RoHS
|

ENVIROMUX-3G
 |

ENVIROMUX-ACVD-515M
ENVIROMUX-ACVD-515
ENVIROMUX-ACVD-C14M
ENVIROMUX-ACVD-C14
 |
- Sends SMS text messages to a cell phone when a sensor goes out of range of a configurable threshold.
- Removable antenna.
- Supports third generation (3G) digital cellular standards.
- Convenient push button SIM card holder.
- Mini SIM card supporting 3G SMS messaging required (not included)
- Protocols: AT commands
- Supports one configurable authorized phone number for sending SMS text messages.
- Tri-band UMTS (HSDPA): 850/1900/2100 MHz
- Quad band EDGE/GPRS/GSM: 850/900/1800/1900 MHz
- Includes 12V/1A power supply.
|
- Measurement range: detects voltage from 50 to 250 VAC.
- Measurement indication: Alarm or Normal.
- Sensor type: open/closed contact switch.
- Attached 0.9 meter power cord.
- ENVIROMUX-ACVD-515M: Standard US 120V 15A NEMA 5-15 plug (When using with ENVIROMUX-MINI that was purchased before 11/1/2007, use part number ENVIROMUX-ACVD-515)
- ENVIROMUX-ACVD-C14M: Universal 250V IEC C14 socket (When using with ENVIROMUX-MINI that was purchased before 11/1/2007, use part number ENVIROMUX-ACVD-C14)
- Regulatory approvals: CE, RoHS.
|